Defibrillator

BMEssentia 医疗城设备实验室中的除颤器。以可交互 3D 打开设备,逐个部件拆解,了解其工作原理,然后在 BMEssentia 平台上系统学习,并向 Essentia 提问。

本页的设备实验室内容为英文,与医疗城中的内容一致。

  • 10 个部件
  • 设备实验室中有 6 种配置
  • 又称: Defib, Aed, Automated External Defibrillator
Defibrillator, BMEssentia Device Library
除颤器,BMEssentia 平台设备库图片。

设备实验室

Defibrillator

This device spends years in a box on a wall, doing nothing, and then has to work perfectly in the hands of a frightened stranger. That combination, years of nothing followed by one attempt with no second chance, shapes everything about how it is built, tested and stored.

部件

逐个部件讲解。

  • Housing

    This device spends years in a box on a wall, doing nothing, and then has to work perfectly in the hands of a frightened stranger. That combination, years of nothing followed by one attempt with no second chance, shapes everything about how it is built, tested and stored.

  • Display

    There is no ECG trace here and that is deliberate. A manual defibrillator shows a clinician a waveform because a clinician can interpret one.

  • Controls

    Count the controls. There are almost none, and that is the single most important design decision in this device.

  • Battery

    This battery will sit unused for years and must then supply a full resuscitation without warning. No other battery in this device family has that duty.

  • Therapy

    On this device the therapy cable is usually already connected, and that is a decision about users rather than about engineering. A cable a bystander has to plug in correctly, under stress, is a step that can be got wrong.

  • Right Pad

    This pad has to be placed correctly by somebody who has never done it, is not being supervised, and is reading a picture. Everything about it, its size, its backing, the diagram printed on it, exists to make a correct placement the obvious one.

  • Left Pad

    The second pad completes the circuit, and where it goes decides what the shock reaches. Two electrodes do not deliver therapy to a place; they deliver it along a path between them.

  • Capacitor

    This store holds enough energy to stop a heart, inside a device that a member of the public opens on a wall. That it can be operated safely by an untrained person is a claim resting entirely on the fact that they can never reach this component, and that the device decides when it is charged.

  • Charger

    This converter has to take a standby battery to defibrillation voltage in the seconds after the device decides to treat, having done almost nothing for years beforehand. It is the least exercised assembly in the device and one of the most critical, which is why the self-test runs it deliberately.

  • Output

    This assembly delivers a defined energy into a patient whose electrical properties nobody has measured, applied by someone with no training, through pads they placed from a picture. It compensates for almost all of that, automatically, in the moment.