Cochlear Nucleus Profile Plus series implant

The Nucleus Profile Plus (CI600 series) is Cochlear's cochlear implant receiver stimulator, offered with several electrode arrays and implanted by ENT surgeons for severe to profound sensorineural hearing loss, then fitted by audiologists with an external sound processor. Its distinguishing features are a 3.9 mm thin titanium body and a removable magnet cassette that is approved for 1.5 T and 3.0 T MRI with the magnet left in place.

The model

Maker, model and type.

Maker
Cochlear Limited
Model
Nucleus Profile Plus series implant (CI600 series: CI612, CI622, CI624, CI632)
Device type
Cochlear Implant
Main document
Open the public document

Key specifications

What the public record says.

ItemValueSource
Electrode optionsCI612 Contour Advance (perimodiolar), CI622 Slim Straight (lateral wall, insertion up to 25 mm), CI632 Slim Modiolar, plus Slim 20 (CI624)Source
Receiver stimulator thickness3.9 mmSource
Weight9.2 g including electrode arraySource
Impact resistanceUp to 2.5 J external impactSource
CaseTitanium, smooth external geometrySource
MRIMR Conditional at 1.5 T and 3.0 T with magnet in place; no head wrap neededSource
Compatible sound processorsNucleus Kanso (CP950), Kanso 2 (CP1150), Nucleus 7 (CP1000), Nucleus 8 (CP1100)Source
FDA approval routePMA P970051 (for example supplement S183, 2019, CI600 series design change)Source

Recalls

Recalls.

This note lists no recalls. Check the FDA recall database for the latest record.

Safety

Safety warnings from the record.

  • The implants are MR Conditional only within defined conditions; read the instructions for use and local MRI guidelines before scanning, since rules differ by country. Source
  • The magnet distorts head images at any field strength, so removal may be needed when the area of interest is near the implant. Source
  • Only Cochlear-approved compatible magnets should be fitted to the implant. Source

Sources

Where this note comes from.

Not covered: No FDA recall for CI600 series implants was found (recalls listed under Cochlear concern older implants and accessories), and the surgeon's guide, MRI guidelines PDF and fitting software documentation were not opened, so electrode counts, stimulation limits, impedance checks and any implant or processor error messages are not included.

BMEssentia knowledge drafted from public information, reviewed by Hasan Khaled Ismail on 2026-10-24. Always follow the manufacturer's instructions for use and service manual.